Tags

, , , , , , , , , , , , , , , , , ,

S106

There was not sufficient storage to load a module. Ensure that the
values for REGION, MAINSIZE, SIZE, RESALL or RESINV are
sufficient.

S804

The amount of storage requested exceeded that available. Ensure that
the values for REGION, MAINSIZE, SIZE, RESALL or RESINV are
sufficient.

S878

User exits required more storage than was available. Ensure that the
values for each user exit size in the MODS statement and for
REGION, MAINSIZE, SIZE, RESALL or RESINV are sufficient.

S80A

This abend can result from the following:
– A DFSORT job required more storage than was available. Ensure
that the values for REGION, MAINSIZE, SIZE, RESALL or RESINV
are sufficient.
– The ‘-1’ flag required to mark the end of an extended parameter list
was missing. Include an F’-1′ to mark the last item in the parameter
list.
– The invoking program used AL3 to define addresses for DFSORT
control statements. Be sure to use full 4-byte addresses to prevent
DFSORT from “running off the end” while allocating storage.

SD37

A SORTWK, SORTOUT, or OUTFIL data set was specified with
insufficient primary space allocation and no secondary allocation.
Increase the primary allocation, or include a value for secondary
allocation.

SE37

A SORTOUT or OUTFIL data set was allocated on a primary volume
that had either insufficient storage or excessive fragmentation, and no
secondary volume was specified. Specify more than one volume in the
VOLSER parameter for the SORTOUT or OUTFIL data set or
compress the volume to allow it to contain the full 16 extents.

——————————————————————————————————–

If you would like to Earn Free Stocks, Credit card Points and Bank account Bonuses, Please visit My Finance Blog

——————————————————————————————————–

You may also like to look at:

Working on Mainframes – Is Change to a different technology necessary
Important SQL CODES and ABEND CODES
SORT JOIN – TO JOIN TWO FILES BASED ON A KEY
KNOW YOUR MAINFRAME
REXX – INITIAL SETUP
HOW TO SUBMIT A BATCH JOB FROM THE CICS PROGRAM
CICS – EXEC interface block – EIBRESP Values
CICS – EXEC interface block Fields
Flow of control between COBOL programs, run units, and CICS
CICS INTERVIEW QUESTIONS
CICS TIPS
COBOL – COPY and INCLUDE statements
COBOL – PERFORMANCE IMPROVEMENT
COBOL – SIGN STORED IN COMP, COMP-3 AND DISPLAY FORMATS
SHORTEST COBOL PROGRAM
RESTART LOGIC IN COBOL DB2 Program
GOBACK – EXIT PROGRAM – STOP RUN
Continuation lines in COBOL
Computational items – COMP, COMP 1 , COMP 2, COMP 3
COBOL program format
cobol indicator area column-7 and area a and area b
COBOL INTERVIEW QUESTIONS
COBOL TIPS
COBOL COMPILER OPTIONS
The IDENTIFICATION DIVISION
Advertisement